Schiller Co Inc
Tel: 305-319-1713 Fax: 305-383-2721
Email: info@schillerco.com Web: www.schillerco.com
|
500
KW, Inlet 425 PSIG/725*f, exh: 1.5" hga, 460V,
3/60hz, 1200 rpm:-1 [34010]
1250 KW, Inlet 525 PSIG/825 *f, GE, 440 V/3/60HZ,
CONDENSING:-1 [33226]
1500 KW, Inlet 525/618 PSIG, 450 V., WESTINGHOUSE,
825*F, 450 VOLT, 1200 RPM;-5 [17169]
2500 KW, Inlet 365/600 PSIG, 440 V., WESTINGHOUSE,
440 VOLT, 6946/1200 RPM;-1 [17172]
2500 KW, TURBODYNE, 400 PSIG/448 *F-10.2"
HGA,480/3/60 HZ:-2 [24539]
3750 KW, Inlet 600 PSIG/675 deg f, AE 80 & 5 PSIG,
EXH: 2"HGA, 13.8 KV/60 HZ:-1 [31835]
4500 KW, Inlet 750 PSIG/750 *F, EXH: 4" HGA,
ELLIOTT, 1980:-1 [33861]
5000 KW, INLET 40 BAR/400 DEG C, EXH: 0.08 kPa
abs,2002, 6.3 kv/3/50 hz:-1 [34987]
5000 KW, Inlet 600 PSIG, 2400 V., GE,-2 [34887]
5900 KW, 11000 V/3/50 HZ, 7500/1500 RPM, 1999 - 1
[34638]
6000 KW, Inlet 1000 PSIG/900*F, AE 280 PSIG, 60 PSIG
EXH:27"HG, 3.1 KV/50 HZ:-1 [34877]
7000 KW, 4160 V/3/60 HZ, 1800 RPM, HAS BOTH LOW &
HIGH PRESSURE TURBINES, 1992 [26660]
7500 KW, Inlet 850 PSIG/825 *F, 2" HG, 50 PSIG,
EXT., 4160 V, GE, 1959, 3600 RPM [24308]
9400 KW, Inlet 900 PSIG @ 825 DEG. F, 12000 V/3/60
HZ, FUJI, 1800 RPM - 1 [26985]
10000 KW, Inlet 600 PSIG/750*f, EXH: 3"HGA, 4160
V/3/60 hz, TERRY, 1988:-1 [34980]
10000 KW, Inlet 64 bar/515 deg c, Ext. 21/13/1.2
Exh. Cond, 6300 v/3/50 hz:-1 [31581]
12500 KW, Inlet 600 PSIG, 12500 V., WESTINGHOUSE,
1955, 825* F, 3600 RPM;-1 [16511]
12500 KW, Inlet 600 PSIG/725*F, EXH: 1.5" HGA, 13.8
KV, 3/60 HZ:-1 [34336]
12500 KW, Inlet 600 PSIG @ 750 DEG F, 13800 V/3/60
HZ, WESTINGHOUSE, 1949 - 1 [29236]
16500 KW, Inlet 850 PSIG, WESTINGHOUSE, 1958, 900*
F, 3600 RPM, 937 AMP;-1 [16512]
18375 KW, Inlet 900 PSIG/900 DEG F, EXH: 2" HGA,
12470 V., TURBODYNE, 1985:-1 [33347]
19000 KW, Inlet 75 PSIG/308*f, Exh: 4" HGA, :-1
[33366]
22000 KW, Inlet 850 PSIG @ 900 DEG F, 13800 V.,
GENERAL ELECTRIC, 1955 - 1 [32821]
22500 KW, Inlet 600 PSIG/750 DEGF, AE 140 PSIG,
EXH:1.5" HGA, 13.8 KV, 1993 :-1 [33810]
40000 KW, Inlet 450 PSIG @ 752 DEG. F, 10500 V/3/50
HZ, BBC, 1974, UNUSED - 2 [32663]
40000 KW, Inlet 2048 PSIG @ 977 DEG F, 10500 V/3/50
HZ., MAN, 1962 - 1 [28509]
42000 KW, Inlet 350 PSIG @ 750 DEG. F, 11 KV/3/60
HZ, GE, 1930, 1800 RPM - 1 [25188]
44000 KW, Inlet 1450 PSIG/1000 RH: 1000*f
EXH;1.5"HGA, 13800 V/3/60 HZ, GE, 1964 [34955]
50000 KW, Inlet 1450 PSIG @ 1000 DEG F, 13800 V.,
ENGLISH ELECTRIC, 1961 - 1 [29351]
50000 KW, Inlet 1450 PSIG/1000*F, RH: 1000*F, EXH:
28.5"HGA, 13800 V/3/60 HZ:-2 [34656]
52000 KW, Inlet 1400 PSIG/730 *f Exh:2.7"hga , shin
nippon, 2007:-1 [34531]
60000 KW, Inlet 1250 PSIG @ 950 DEG. F, 12500 V/3/60
HZ, GE, 3600 RPM - 2 [33413]
66000 KW, Inlet 1250 PSIG, GENERAL ELECTRIC, 1952,
950* F, 3600 RPM;-2 [18069]
75000 KW, Inlet 1800 PSIG/1000 *f, RH:1000*F,
EXH:1"HGA, 13.8 KV,3/60 HZ:-1 [34654]
85000 KW, WESTINGHOUSE, Inlet 386 PSIG,1000*F,
EXH:1.5" HG, 14400 V., - 1 [33799]
105000 KW, GENERAL ELECTRIC, Inlet 1250 PSIG, 950*F,
EXH: 3" HG, 13800 V., -1 [21505]
117000 KW, Inlet 1800 PSIG @ 1000 DEG F, 13800
V/3/50 HZ, AEI, 3000 RPM - 3 [31988]
125 mw GE, 1250 PSIG/950 deg F inlet, cross-compound
gen set, qty-1 [27364]
125000 KW, Inlet 1250 PSIG @ 950 DEG F, 13800 V,
3600 RPM, WESTINGHOUSE, 1945-1 [27365]
140000 KW, Inlet 1900 PSIG/1050 DEG F, 15750 V/3/50
HZ,ALSTOM 3000 RPM - 2 [33966]
146430 KW, Inlet 1800 PSIG/1000 *F, RH 1000*F, 14400
V/3/60 HZ, 1974:-1 [34053]
150000 KW, Inlet 113 PSIG/350*F, EXH:2"HGA, 13800
V., MITSUBISHI, 1989,UNUSED:-1 [34956]
156000 KW, Inlet 1800 PSIG @ 1000 DEG F, GE, 3600
RPM, TANDEM COMPOUND - 2 [34756]
158955 KW, Inlet 1300 PSIG/950*f, exh: 2" hga, 18
kv/3/60 hz, GE, 1990:-2 [34861]
160000 KW, Inlet 645 PSIG, WESTINGHOUSE, 1968,
EXH:1.8" HG - 1 [34935]
160000 KW, Inlet 1800 PSIG, 13800 V., GE,
1955,Reheat, Cross Compound, Qty-2 [26532]
160000 KW, 3/50 HZ, WESTINGHOUSE, 1960'S - 1 [34747]
185000 KW, Inlet 2350 PSIG @ 1050 DEG. F, 13800
V/3/60 HZ, WESTINGHOUSE, 1955-1 [23222]
190000 KW, Inlet 1800 PSIG/1000 *F, RH 1000*F, 2"
HGA, 20 KV/3/60 HZ, 1977:-1 [34064]
300/200 MW, Oil/Coal,Unused,2400 PSIG, 17K V, GEC,
1981, Power Plant, -1 [17810]
240000 KW, GE, D11 , 18 KV, 3 PHASE, 60 HZ, UNUSED,
2001:-1 [31108]
1130000 KW, Inlet 875 PSIG, GENERAL ELECTRIC, 1800
RPM, 1280 MVA 0.8 PF;-1 [11476]
|
|
Return
|